ViWa BioCare

XH-80 Patient Monitoring System

Sorry, this product is currently unavailable.

Please Contact Us for assistance finding the best alternative!

Description

The ICU series of patient monitors are specifically designed to meet the daily clinical needs of healthcare professionals and seamlessly integrate into hospital workflows. With a modular framework and interface, these monitors can be easily customized to meet specific clinical parameters, providing maximum flexibility in acute care and intensive care settings. These patient monitors are highly reliable and user-friendly, offering advanced parameters and easy access to patient data. They are an ideal choice for acute care and intensive care, where reliable and accurate monitoring is crucial. Additionally, the monitors are lightweight and easy to carry, making them a practical choice for in- and out-of-hospital transfers. The powerful and intuitive user interface further enhances their usability, making them an excellent asset for healthcare professionals in a variety of clinical settings. Overall, these of patient monitors provide the precision, reliability, and flexibility that healthcare professionals require to provide optimal patient care

SKU:
100267849
Seller:
ViWa BioCare
Type:
ViWa BioCare
  • SPO2
    • Range: 0~100%
    • Accuracy: ±2% (70%~100%), Undefined (<70%)
    • Resolution: 1%
  • AwRR (Air Way Respiratory Rate)
    • Range: 0~150 rpm
    • Accuracy: ±1 rpm (0~70 rpm), Undefined (within other ranges)
    • Resolution: 1 rpm
  • PR
    • Range: 25~250 bpm
    • Accuracy: ±2 bpm or ±2% (whichever is greater)
    • Resolution: 1 bpm
  • EtCO2
    • Range: 0~20 vol%
    • Accuracy:
      • 0~12 vol%: ±(0.2 vol% + 2% of reading)
      • 12~20 vol%: ±(0.2 vol% + 6% of reading)
    • Resolution: 1 mmHg
  • TEMP
    • Range: 0-50°C
    • Accuracy: ±0.1°C
    • Resolution: 0.1
  • ECG
    • ECG Range: 0.15~5.5 mV
    • ECG Resolution: 2.36 µV/LSB
    • HR Range:
      • Adult: 15~300 bpm
      • Child/Neonate: 15~350 bpm
    • HR Accuracy: ±1 bpm or ±1% (whichever is greater)
  • NIBP
    • Pressure Range: 0~300 mmHg
    • Pressure Accuracy: ±2 mmHg or ±1% of reading (take the larger value)
    • Resolution: 1 mmHg
    • SYS Range:
      • Adult: 40-270 mmHg
      • Pediatric: 40-200 mmHg
      • Neonate: 40-130 mmHg
    • DIA Range:
      • Adult: 10-210 mmHg
      • Pediatric: 10-162 mmHg
      • Neonate: 10-90 mmHg
    • Mean Range:
      • Adult: 20-230 mmHg
      • Pediatric: 20-170 mmHg
      • Neonate: 20-100 mmHg
    • Accuracy: The mean deviation < ±5 mmHg. The standard deviation < 8 mmHg