Description
3M 1870+ Aura N95 P2 Flat Fold Respirator Surgical Mask Individually Packed
3M 1870+ Aura N95 P2 Flat Fold Respirator Surgical Mask Individually Packed
3M 1870+ Aura N95 P2 Flat Fold Respirator Surgical Mask
- Made in the USA
- FITS A WIDE RANGE OF FACE SHAPES AND SIZES
- CURVED LOW-PROFILE DESIGN conforms well to nose and eye contours, allowing more room for eyewear
- DESIGNED TO DIRECT EXHALED AIR AWAY FROM THE NOSE PANEL, helping reduce eyewear fogging
- INNOVATIVE CHIN TAB designed for ease of positioning, donning and adjustment
- INDIVIDUAL PACKAGING and flat fold design provide convenient storage and portability prior to use
- Department name: unisex-adult
Fitting Instructions
Must be followed each time the respirator is worn. Before fitting device, ensure hands are clean.
- All respirator components should be inspected for damage prior to each use.
- With reverse side up and using the tab, separate top and bottom panels to form a cup shape. Bend slightly at centre of the nose clip.
- Ensure both panels are fully unfolded.
- Cup respirator in one hand with open side towards face.
- Take both straps in other hand. Hold respirator under chin, with nose piece up, and pull straps over head.
- Locate the upper strap across the crown of the head
and the lower strap below the ears. Straps must not be twisted. Adjust top and bottom panels for comfortable fit, ensuring panels and chin tab are not folded in. - Using both hands, mould nose clip to the shape of the lower part of the nose to ensure a close fit and good seal.
- Pinching the nose clip using only one hand may result in less effective respirator performance use two hands.
- The seal of the respirator on the face should be fit checked before entering the workplace
Use For
- Intended to be worn by operating room personnel during surgical procedures to help protect both the surgical patient and the operating room personnel from transfer of microorganisms, body fluids, and particulate material.
- Always follow User Instructions and use in manners as indicated..
Do Not Use for
- DO NOT use in industrial settings
- DO NOT use for gases or vapours (i.e. anaesthetic gases such as isoflurane or vapours from sterilant such as glutaraldehyde.)
- DO NOT use in any manner not indicated in the User Instructions
Storage and Transportation
Shelf life of the unopened product is five (5) years from date of manufacture when stored within temperature range of -20°C to +30°C and at less than 80% relative humidity. End of shelf life date is marked on the product packaging. Before initial use, always check that the product is within the stated shelf life. When storing or transporting this product use
original packaging provided. 3M 1870+ Aura N95 P2 Flat Fold Respirator Surgical Mask
3M 1870+ Aura N95 P2 Flat Fold Respirator Surgical Mask Individually Pack
FAQ
How is a respirator different from a surgical mask?
Surgical masks are designed to help reduce patient or health care worker exposures from wearer-generated microorganisms. Fluid resistant masks also help reduce potential exposure of the wearer to blood and body fluids.
Respirators are designed to help protect the wearer from certain airborne contaminants. They also have a snug fit around the face to help avoid leaks where contaminants may enter. Most surgical masks do not have the same filtering capability and typically do not have the same snug fit and, consequently, cannot replace respirators in helping provide respiratory protection. The 1860 and 1870 3M Particulate Respirator and Surgical Masks are both certified as a respirator by NIOSH and are cleared to be used as surgical masks in the OR by the Food and Drug Administration (FDA).
Are the 1860, 1860S and 1870 respirators appropriate for reducing exposure to M. tuberculosis?
These particulate respirators are appropriate where the use of an N95 respirator is recommended. They meet the criteria for a respirator given in the Centers for Disease Control and Prevention (CDC) Guidelines for Preventing the Transmission of Mycobacterium Tuberculosis in Health Care Facilities, 1994. OSHA accepts the use of an N95 respirator during occupational exposure to TB.
Can the 1860 or 1870N95 respirator be used in surgery?
Yes. Both the 1860 and 1870 respirators are cleared for use as a surgical mask by the FDA. In addition to being N95 respirators, they also provide greater than 99% bacterial filtration efficiency against wearer generated particles according to the Modified Greene and Vesley test method.They are also fluid resistant to help reduce exposure to blood and body fluids. When worn properly and in combination with protective eyewear, they comply with the OSHA Bloodborne Pathogens Standard. Fit testing is not required when worn solely as a surgical mask.
Can the 1860 and 1870 respirators be used for laser and electrocautery procedures?
Yes! In addition to recommended healthcare procedures that a smoke evacuator should be used to reduce the amount of smoke in the environment, these respirators may be used to further reduce the wearer’s exposure to electrocautery and laser plume, offering higher filtration and increased facial seal over standard surgical masks.
Do respirators require fit testing?
Yes! OSHA requires that a respiratory protection program be developed for the proper use of these products as with all respirators when used for respirator protection. This includes written procedures, medical screening, training and fit testing. 3M offers the FT-10 Qualitative Fit Test Apparatus, which uses a saccharin aerosol, or the FT-30 Qualitative Fit Test Apparatus, which uses a bitter aerosol, for fit testing. These 10-20 minute fit test procedures demonstrate that an employee can attain a good face fit with a given style respirator.
- SKU:
- 100371354
- Seller:
- Werko (New)